MCA Binary Data Format
MCA Binary Data Format
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - MCA Binary Data Format

MCA-527Multi-Channel AnalyzersGBS Elektronik GmbHBautzner Landstraße 2201454 GroßerkmannsdorfGermanyTel.: 0049 (0)351 21 70 07 - 0Fax: 0049 (0)351

Pagina 2

MCA5273 General mode = 'Timestamps recorder' (= 3, 4 or 5)This file format is used by the 'Timestamps Recorder' computer program t

Pagina 3 - Table of Contents

MCA binary data formatPosition Name Data type ReferencesByte offset 112 Start time unsigned long CMD_QUERY_STATE, byte offset 100Byte offset 116 Real

Pagina 4 - 1 Introduction

MCA527Position Name Data type ReferencesByte offset 196 AHRC group 3 width unsigned long CMD_QUERY_STATE527_EX2, byte offset 12Byte offset 200 AHRC gr

Pagina 5 - 2.1 Basis file block

MCA527Exclusion of liabilityThe information in this document has been carefully reviewed and is believed to beaccurate and reliable

Pagina 6

MCA binary data formatTable of Contents1 Introduction...

Pagina 7

MCA5271 IntroductionThe MCA binary data format has been developed by us for the present applications of the MCA527, however, it is also designed tobe

Pagina 8

MCA binary data format2 General mode = 'MCA' (= 0)In this general mode the MCA527 runs as an ordinary multi-channel analyzer. 2.1 Basis file

Pagina 9 - 2.2 File blocks

MCA527Position Name Data type ReferencesByte offset 102 Preamplifier power switches unsigned short CMD_QUERY_STATE, byte offset 60Byte offset 104 PZC

Pagina 10 - 3.1 Basis file block

MCA binary data formatPosition Name Data type ReferencesByte offset 170 Start flag unsigned short CMD_QUERY_STATE, byte offset 130Byte offset 172 Star

Pagina 11 - MCA binary data format

MCA527Position Name Data type ReferencesByte offset 268Time window 2 width for gating mode 'sort by time'unsigned long CMD_QUERY_STATE527_EX

Pagina 12 - 3.2 File blocks

MCA binary data format2.2 File blocksBasis file blockThis file block already exists. It is 512 bytes long. See above.User data This file block alrea